Ultrasonic Watermeters read water flow by the help of two ultrasonic probes positioned in the same axis.
In case of a velocity change, variance in ultrasonic waves is detected by the probe and by the help of the processor; these variances are converted into flow rate data.
Flowrate and Consumption Values can be read from the IP68 protected LED Screen.
Furthermore, it provides an alarm in low battery conditions. Internal Lithium Battery can provide power up to 10 years autonomously.
As for communications, the meter has an M-Bus and Optic interface as standard and Pulse or RF interface can be provided optionally.
Pump Control Valves protect pumps, pipelines, and other system components by isolating the pipeline from the sudden velocity changes associated with pump starting and stopping.
The “Active Check Valve” logic of operation, is the method of pumping system control that prevents surges rather than eliminating them.
Underground Air Valves that can be buried under soil are designed to perform three functions:
1. Venting of large volumes of air on the start-up of the system, while pipelines are filled.
2. Intake of large volumes of air on shut-off of the system, which pipelines are being drained.
3. Discharge of pressurized air pockets during the operation.
Due to its Stainless Steel Sleeve, the valve can be buried under soil. As a result, no need for an expensive valve chamber is needed.
Moreover, it does not require any external isolation valve, due to its integral automatic closing mechanism. The valve can be serviced from a Surface Box and taken out for cleaning or maintenance.
Y Type Strainers are installed to protect system appliances, such as: pumps, flowmeters, control valves or regulating devices.
The main function is to remove foreign matter like leaves, sticks or stones from the pipelines. Foreign particles that can harm crucial appliances in the system are stuck in the filter of the strainer, and the user can check the blockage of the filter by using monometer connections.
In case of a situation where the differential pressure reading is high, the blow-off port is used to remove entrapped debris at the bottom of the body.
Y Type Strainers feature large trap capacity, low head loss and ease of both cleaning and handling..
Basket Type Strainers are installed to protect system appliances, such as: pumps, flowmeters, control valves or regulating devices.
The main function is to remove foreign matter like leaves, sticks or stones from the pipelines. Foreign particles that can harm crucial appliances in the system are stuck in the filter of the strainer, and the user can check the blockage of the filter by using monometer connections.
In case of a situation where the differential pressure reading is high, the blow-off port is used to remove entrapped debris at the bottom of the body.
Due to its design, Basket Type Strainers feature much bigger trap capacity compared to other types of strainers. Furthermore, service from the top cover enable a more shallow Valve Chamber, thereby decreasing the overall cost of the installation.