Lift Check Valves has a disc that lifts up off its seat by higher inlet pressure. When the inlet pressure drops, the disc is closed before the back-flow reaches to the valve, enabling non-slam & drip tight closure.
It has a relatively short valve disc travel resulting in an immediate valve disc closing on no flow conditions, minimizing water hammer and surge conditions.
Lift Check Valve has a center-guided, spring loaded valve disc with a resilient seal, acting over a bronze or stainless steel removable valve seat.
It can be furnished with valve position indicator and electrical limit switches and can be serviced without being removed from the pipeline.
Aboveground Fire Hydrants are made of ductile iron body, valve mechanism, and a spindle that controls the sealing.
When the head of the hydrant is turned counter clockwise, the spindle moves down, sealing the valve at the flow direction. In the reverse action, fire hydrant shuts-off drip tight.
Aboveground Fire Hydrants can be manufactured with 3 different lengths for various pipeline depths.
Basket Type Strainers are installed to protect system appliances, such as: pumps, flowmeters, control valves or regulating devices.
The main function is to remove foreign matter like leaves, sticks or stones from the pipelines. Foreign particles that can harm crucial appliances in the system are stuck in the filter of the strainer, and the user can check the blockage of the filter by using monometer connections.
In case of a situation where the differential pressure reading is high, the blow-off port is used to remove entrapped debris at the bottom of the body.
Due to its design, Basket Type Strainers feature much bigger trap capacity compared to other types of strainers. Furthermore, service from the top cover enable a more shallow Valve Chamber, thereby decreasing the overall cost of the installation.
Ultrasonic Watermeters read water flow by the help of two ultrasonic probes positioned in the same axis.
In case of a velocity change, variance in ultrasonic waves is detected by the probe and by the help of the processor; these variances are converted into flow rate data.
Flowrate and Consumption Values can be read from the IP68 protected LED Screen.
Furthermore, it provides an alarm in low battery conditions. Internal Lithium Battery can provide power up to 10 years autonomously.
As for communications, the meter has an M-Bus and Optic interface as standard and Pulse or RF interface can be provided optionally.
C Type Irrigation Hydrants have a special closing mechanism enabling gradual flow increase/decrease when the handwheel is turned, preventing slam closure.
Hydrants are available with an optional anti-frost sleeve for deep water networks, and an automatic drainage valve to bleed the body when the hydrant is closed, to prevent frost damages.
Nozzles that are used in hydrant connection have integral pressure regulator and flow limiter in order to provide constant pressure and flow rate to the farmer. Number of nozzles on the body can be increased up to 4 outlets, enabling supply to more than one farmer from a single hydrant.
Reviews